1.
J Clin Med ; 12(20)2023 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-37892736

RESUMO

Herein, we provide evidence that human regulation of aqueous outflow is by a pump-conduit system similar to that of the lymphatics. Direct observation documents pulsatile aqueous flow into Schlemm's canal and from the canal into collector channels, intrascleral channels, aqueous veins, and episcleral veins. Pulsatile flow in vessels requires a driving force, a chamber with mobile walls and valves. We demonstrate that the trabecular meshwork acts as a deformable, mobile wall of a chamber: Schlemm's canal. A tight linkage between the driving force of intraocular pressure and meshwork deformation causes tissue responses in milliseconds. The link provides a sensory-motor baroreceptor-like function, providing maintenance of a homeostatic setpoint. The ocular pulse causes meshwork motion oscillations around the setpoint. We document valves entering and exiting the canal using real-time direct observation with a microscope and multiple additional modalities. Our laboratory-based high-resolution SD-OCT platform quantifies valve lumen opening and closing within milliseconds synchronously with meshwork motion; meshwork tissue stiffens, and movement slows in glaucoma tissue. Our novel PhS-OCT system measures nanometer-level motion synchronous with the ocular pulse in human subjects. Movement decreases in glaucoma patients. Our model is robust because it anchors laboratory studies to direct observation of physical reality in humans with glaucoma.

2.
PLoS One ; 18(2): e0280738, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36812261

RESUMO

Professional service firms apply specialist knowledge to create customised solutions to client problems. In their work, teams of professionals undertake projects in which clients may be closely involved in co-creating solutions. However, we know little about the conditions under which client involvement contributes to better performance. We examine the direct and conditional contribution client involvement can make to project success and propose team bonding capital as a moderator. We conduct multi-level analysis of data from 58 project managers and 171 consultants nested in project teams. We find a positive impact of client involvement on both team performance and team member idea creativity. Team bonding capital moderates the relationships client involvement has with both team performance and individual member idea creativity, where the impact of client involvement is greater when team bonding capital is high. Implications for theory and practice are discussed.

3.
Bioengineering (Basel) ; 9(11)2022 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-36354583

RESUMO

BACKGROUND: Aqueous humor outflow resistance in the trabecular meshwork (TM), juxtacanalicular connective tissue (JCT), and Schlemm's canal (SC) endothelium of the conventional outflow pathway actively contribute to intraocular pressure (IOP) regulation. Outflow resistance is actively affected by the dynamic outflow pressure gradient across the TM, JCT, and SC inner wall tissues. The resistance effect implies the presence of a fluid-structure interaction (FSI) coupling between the outflow tissues and the aqueous humor. However, the biomechanical interactions between viscoelastic outflow tissues and aqueous humor dynamics are largely unknown. METHODS: A 3D microstructural finite element (FE) model of a healthy human eye TM/JCT/SC complex was constructed with elastic and viscoelastic material properties for the bulk extracellular matrix and embedded elastic cable elements. The FE models were subjected to both idealized and a physiologic IOP load boundary using the FSI method. RESULTS: The elastic material model for both the idealized and physiologic IOP load boundary at equal IOPs showed similar stresses and strains in the outflow tissues as well as pressure in the aqueous humor. However, outflow tissues with viscoelastic material properties were sensitive to the IOP load rate, resulting in different mechanical and hydrodynamic responses in the tissues and aqueous humor. CONCLUSIONS: Transient IOP fluctuations may cause a relatively large IOP difference of ~20 mmHg in a very short time frame of ~0.1 s, resulting in a rate stiffening in the outflow tissues. Rate stiffening reduces strains and causes a rate-dependent pressure gradient across the outflow tissues. Thus, the results suggest it is necessary to use a viscoelastic material model in outflow tissues that includes the important role of IOP load rate.

4.
J Clin Med ; 11(20)2022 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-36294371

RESUMO

BACKGROUND: Although the tissues comprising the ocular conventional outflow pathway have shown strong viscoelastic mechanical response to aqueous humor pressure dynamics, the viscoelastic mechanical properties of the trabecular meshwork (TM), juxtacanalicular connective tissue (JCT), and Schlemm's canal (SC) inner wall are largely unknown. METHODS: A quadrant of the anterior segment from two human donor eyes at low- and high-flow (LF and HF) outflow regions was pressurized and imaged using optical coherence tomography (OCT). A finite element (FE) model of the TM, the adjacent JCT, and the SC inner wall was constructed and viscoelastic beam elements were distributed in the extracellular matrix (ECM) of the TM and JCT to represent anisotropic collagen. An inverse FE-optimization algorithm was used to calculate the viscoelastic properties of the ECM/beam elements such that the TM/JCT/SC model and OCT imaging data best matched over time. RESULTS: The ECM of the glaucoma tissues showed significantly larger time-dependent shear moduli compared to the heathy tissues. Significantly larger shear moduli were also observed in the LF regions of both the healthy and glaucoma eyes compared to the HF regions. CONCLUSIONS: The outflow tissues in both glaucoma eyes and HF regions are stiffer and less able to respond to dynamic IOP.

5.
Front Cell Dev Biol ; 10: 868029, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35859902

RESUMO

Purpose: The aim of the study was 1) to describe a novel combination of techniques that permit immunohistochemistry imaging of Schlemm's canal inlet (SIV) and outlet (SOV) valve-like structures, 2) to identify tissue-level SIV adhesive relationships linking the trabecular meshwork (TM) to hinged collagen leaflets at the Schlemm's canal (SC) external wall, and 3) to determine whether the SIV lumen wall's adhesive vascular markers are similar to those of the SC inner wall endothelium. Materials and Methods: Anterior segments of 16 M. nemestrina primates underwent immunohistochemistry (IHC) labeling. We perfused fluorescent microspheres into 12 of the eyes. Limbal tissues were divided into quadrants, viscoelastic introduced into SC, tissues fixed, immunohistochemistry performed, radial segments cut, tissues clarified, and confocal microscopy performed. Finally, we generated ImageJ 3D projections encompassing the TM, SC, and distal pathways. Results: IHC imaging identified 3D relationships between SIV, collector channel ostia, collector channels (CC), SOV, and intrascleral channels. Imaging depth increased 176.9%, following clarification (p < 0.0001). Imaging demonstrated CD31, collagen type 1 and 4 in the walls of the SIV lumen and more distal pathways. In eight eyes, 384 segments were examined, 447 SIV identified, and 15.4% contained microspheres. Conclusion: Our technique's imaging depth permitted the identification of SIV linkage between the TM and SOV. We found comparable cell-cell adhesion molecules (CD31) and basement membrane components in the SC inner wall and SIV lumen walls. Recent OCT studies have suggested that SIV tensional relationships may control CC entrance dimensions that regulate distal resistance. Cellular adhesive properties sustain SIV tensional relationships. These SIV cell-cell and cell-basement membrane properties warrant further study because abnormalities could be a factor in the IOP elevation of glaucoma.

6.
Comput Methods Programs Biomed ; 221: 106922, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35660940

RESUMO

BACKGROUND AND OBJECTIVE: Intraocular pressure (IOP) is determined by aqueous humor outflow resistance, which is a function of the combined resistance of Schlemm's canal (SC) endothelium and the trabecular meshwork (TM) and their interactions in the juxtacanalicular connective tissue (JCT) region. Aqueous outflow in the conventional outflow pathway results in pressure gradient across the TM, JCT, and SC inner wall, and induces mechanical stresses and strains that influence the geometry and homeostasis of the outflow system. The outflow resistance is affected by alteration in tissues' geometry, so there is potential for active, two-way, fluid-structure interaction (FSI) coupling between the aqueous humor (fluid) and the TM, JCT, and SC inner wall (structure). However, our understanding of the biomechanical interactions of the aqueous humor with the outflow connective tissues and its contribution to the outflow resistance regulation is incomplete. METHODS: In this study, a microstructural finite element (FE) model of a human eye TM, JCT, and SC inner wall was constructed from a segmented, high-resolution histologic 3D reconstruction of the human outflow system. Three different elastic moduli (0.004, 0.128, and 51.5 MPa based on prior reports) were assigned to the TM/JCT complex while the elastic modulus of the SC inner wall was kept constant at 0.00748 MPa. The hydraulic conductivity was programmed separately for the TM, JCT, and SC inner wall using a custom subroutine. Cable elements were embedded into the TM and JCT extracellular matrix to represent the directional stiffness imparted by anisotropic collagen fibril orientation. The resultant stresses and strains in the outflow system were calculated using fluid-structure interaction method. RESULTS: The higher TM/JCT stiffness resulted in larger stresses, but smaller strains in the outflow connective tissues, and resulted in a 4- and 5-fold larger pressure drop across the SC inner wall, respectively, compared to the most compliant model. Funneling through µm-sized SC endothelial pores was evident in the models at lower tissue stiffness, but aqueous flow was more turbulent in models with higher TM/JCT stiffness. CONCLUSIONS: The mechanical properties of the outflow tissues play a crucial role in the hydrodynamics of the aqueous humor in the conventional outflow system.


Assuntos
Humor Aquoso , Malha Trabecular , Humor Aquoso/metabolismo , Fenômenos Biomecânicos , Humanos , Hidrodinâmica , Pressão Intraocular , Malha Trabecular/metabolismo
7.
Comput Methods Programs Biomed ; 221: 106921, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35660943

RESUMO

BACKGROUND AND OBJECTIVE: The trabecular meshwork (TM) consists of extracellular matrix (ECM) with embedded collagen and elastin fibers providing its mechanical support. TM stiffness is considerably higher in glaucoma eyes. Emerging data indicates that the TM moves dynamically with transient intraocular pressure (IOP) fluctuations, implying the viscoelastic mechanical behavior of the TM. However, little is known about TM viscoelastic behavior. We calculated the viscoelastic mechanical properties of the TM in n = 2 healthy and n = 2 glaucoma eyes. METHODS: A quadrant of the anterior segment was submerged in a saline bath, and a cannula connected to an adjustable saline reservoir was inserted into Schlemm's canal (SC). A spectral domain-OCT (SD-OCT) provided continuous cross-sectional B-scans of the TM/JCT/SC complex during pressure oscillation from 0 to 30 mmHg at two locations. The TM/JCT/SC complex boundaries were delineated to construct a 20-µm-thick volume finite element (FE) mesh. Pre-tensioned collagen and elastin fibrils were embedded in the model using a mesh-free penalty-based cable-in-solid algorithm. SC pressure was represented by a position- and time-dependent pressure boundary; floating boundary conditions were applied to the other cut edges of the model. An FE-optimization algorithm was used to adjust the ECM/fiber mechanical properties such that the TM/JCT/SC model and SD-OCT imaging data best matched over time. RESULTS: Significantly larger short- and long-time ECM shear moduli (p = 0.0032), and collagen (1.82x) and elastin (2.72x) fibril elastic moduli (p = 0.0001), were found in the TM of glaucoma eyes compared to healthy controls. CONCLUSIONS: These findings provide additional clarity on the mechanical property differences in healthy and glaucomatous outflow pathway under dynamic loading. Understanding the viscoelastic properties of the TM may serve as a new biomarker in early diagnosis of glaucoma.


Assuntos
Glaucoma , Malha Trabecular , Fenômenos Biomecânicos , Estudos Transversais , Elastina/metabolismo , Glaucoma/diagnóstico por imagem , Humanos , Malha Trabecular/metabolismo
8.
Front Med (Lausanne) ; 9: 815866, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35572956

RESUMO

Purpose: This study aimed to investigate anatomic relationships and biomechanics of pressure-dependent trabecular meshwork and distal valve-like structure deformation in normal and glaucoma eyes using high-resolution optical coherence tomography (HR-OCT). Methods: We controlled Schlemm's canal (SC) pressure during imaging with HR-OCT in segments of three normal (NL) and five glaucomatous (GL) ex vivo eyes. The dissected limbal wedges were studied from 15 locations (5 NL and 10 GL). A minimally invasive glaucoma surgery (MIGS)-like cannula was inserted into the SC lumen, whereas the other end was attached to a switch between two reservoirs, one at 0, the other at 30 mm Hg. A steady-state pressure of 30 mm Hg was maintained to dilate SC and collector channels (CC) during 3D volume imaging. The resulting 3D lumen surface relationships were correlated with internal structural features using an image mask that excluded tissues surrounding SC and CC. While imaging with HR-OCT, real-time motion responses in SC and CC areas were captured by switching pressure from 0 to 30 or 30 to 0 mm Hg. NL vs. GL motion differences were compared. Results: Lumen surface and internal relationships were successfully imaged. We identified SC inlet and outlet valve-like structures. In NL and GL, the mean SC areas measured at the steady-state of 0 and 30 mm Hg were each significantly different (p < 0.0001). Synchronous changes in SC and CC lumen areas occurred in <200 ms. Measured SC area differences at the steady-state 0 and 30 mmHg, respectively, were larger in NL than GL eyes (p < 0.0001). The SC motion curves rose significantly more slowly in GL than NL (p < 0.001). Pressure waves traveled from the cannula end along the SC lumen to CC and deep intrascleral channels. Conclusion: HR-OCT provided simultaneous measurements of outflow pathway lumen surfaces, internal structures, and biomechanics of real-time pressure-dependent dimension changes. We identified SC inlet and outlet valve-like structures. GL tissues underwent less motion and responded more slowly than NL, consistent with increased tissue stiffness. A MIGS-like shunt to SC permitted pulse waves to travel distally along SC lumen and into CC.

9.
J Clin Med ; 11(10)2022 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-35628823

RESUMO

(1) Background: To investigate the value of pulsatile trabecular meshwork (TM) motion in predicting the diurnal intraocular pressure (IOP) fluctuation of primary open-angle glaucoma (POAG). (2) Methods: This cross-sectional study recruited 20 normal patients and 30 patients with POAG. Of the POAG group, 20 had stable diurnal IOP and 10 had high IOP fluctuation. A clinical prototype phase-sensitive optical coherence tomography (PhS-OCT) model was used to measure TM pulsatile motion with maximum velocity (MV) and cumulative displacement (CDisp). (3) Results: MV and CDisp were higher in the external region in both normal and POAG patients. All MV and CDisp reduced significantly in the POAG group (p < 0.001). In the POAG group, except MV in the external region (p = 0.085), MV and CDisp in the nasal area were significantly higher than those in the temporal area (p < 0.05). The MV and CDisp in the external region in the nasal area of POAG patients with high IOP fluctuation were much lower than those with stable IOP (pEMV3 = 0.031, pECDisp3 < 0.001); (4) Conclusions: Pulsatile TM motion reduced in POAG patients relevant to the level of diurnal IOP fluctuation. This study presents the segmental variance of TM stiffness in human living eyes and suggests the clinical potential of the measurement of pulsatile TM motion with PhS-OCT for the evaluation of diurnal IOP fluctuation.

10.
Life (Basel) ; 11(2)2021 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-33672433

RESUMO

OBJECTIVE: To evaluate the change of biomechanical properties of the trabecular meshwork (TM) and configuration of collector channels (CC) by high-resolution optical coherence tomography (HR-OCT) induced by Schlemm's canal (SC) dilation. METHODS: The anterior segments of two human eyes were divided into four quadrants. One end of a specially designed cannula was placed in SC and the other end connected to a perfusion reservoir. HR-OCT provided three-dimensional (3D) volumetric and two-dimensional (2D) cross-sectional imaging permitting assessment of the biomechanical properties of the TM. A large fluid bolus was introduced into SC. Same-sample, pre and post deformation and disruption of SC and CC lumen areas were analyzed. RESULTS: Morphologic 3D reconstructions documented pressure-dependent changes in lumen dimension of SC, CC, and circumferential intrascleral channels. 2D imaging established volumetric stress-strain curves (elastance curves) of the TM in quadrants. The curves of TM elastance shift to the right with an increase in pressure-dependent steady-state SC area. After a bolus disruption, the SC area increased, while the CC area decreased. CONCLUSION: Our experimental setup permits the study of the biomechanical properties of TM by examining elastance, which differs segmentally and is altered by mechanical expansion of SC by a fluid bolus. The study may shed light on mechanisms of intraocular pressure control of some glaucoma surgery.

11.
Prog Retin Eye Res ; 83: 100917, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33217556

RESUMO

We propose an integrated model of aqueous outflow control that employs a pump-conduit system in this article. Our model exploits accepted physiologic regulatory mechanisms such as those of the arterial, venous, and lymphatic systems. Here, we also provide a framework for developing novel diagnostic and therapeutic strategies to improve glaucoma patient care. In the model, the trabecular meshwork distends and recoils in response to continuous physiologic IOP transients like the ocular pulse, blinking, and eye movement. The elasticity of the trabecular meshwork determines cyclic volume changes in Schlemm's canal (SC). Tube-like SC inlet valves provide aqueous entry into the canal, and outlet valve leaflets at collector channels control aqueous exit from SC. Connections between the pressure-sensing trabecular meshwork and the outlet valve leaflets dynamically control flow from SC. Normal function requires regulation of the trabecular meshwork properties that determine distention and recoil. The aqueous pump-conduit provides short-term pressure control by varying stroke volume in response to pressure changes. Modulating TM constituents that regulate stroke volume provides long-term control. The aqueous outflow pump fails in glaucoma due to the loss of trabecular tissue elastance, as well as alterations in ciliary body tension. These processes lead to SC wall apposition and loss of motion. Visible evidence of pump failure includes a lack of pulsatile aqueous discharge into aqueous veins and reduced ability to reflux blood into SC. These alterations in the functional properties are challenging to monitor clinically. Phase-sensitive OCT now permits noninvasive, quantitative measurement of pulse-dependent TM motion in humans. This proposed conceptual model and related techniques offer a novel framework for understanding mechanisms, improving management, and development of therapeutic options for glaucoma.


Assuntos
Humor Aquoso , Glaucoma , Humanos , Pressão Intraocular , Esclera , Malha Trabecular
12.
Invest Ophthalmol Vis Sci ; 61(14): 21, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33326017

RESUMO

Purpose: The purpose of this study was to investigate the difference in pulsatile trabecular meshwork (TM) motion between normal and eyes with POAG using phase-sensitive optical coherence tomography (PhS-OCT). Methods: In this cross-sectional study, eight healthy subjects (16 eyes) and nine patients with POAG (18 eyes) were enrolled. A laboratory-based prototype PhS-OCT system was used to measure pulsatile TM motion. PhS-OCT images were analyzed to obtain parameters of pulsatile TM motion (i.e. maximum velocity [MV] and cumulative displacement [CDisp]). Outflow facility and ocular pulse amplitude were measured using pneumotonography. Detection sensitivity was compared among various parameters by calculating the area under the receiver operating characteristic curves (AUCs). Results: A pulsatile TM motion waveform synchronous with digital pulse was observed using PhS-OCT in both healthy and POAG eyes. The mean MV in eyes with glaucoma was significantly lower than healthy eyes (P < 0.001). The mean CDisp in POAG eyes was also significantly lower than healthy eyes (P < 0.001). CDisp showed a significant correlation (r = 0.46; P = 0.0088) with ocular pulse amplitude in the study. Compared with the outflow facility, both the MV and CDisp were found to have a better discrimination of glaucoma (P < 0.001 and P = 0.0074, respectively). Conclusions: Pulsatile TM motion was reduced in patients with POAG compared to healthy subjects. The underlying mechanism may be due to the altered tissue stiffness or other biomechanical properties of the TM in POAG eyes. Our evidence suggests that the measurement of pulsatile TM motion with PhS-OCT may help in characterizing outflow pathway abnormalities.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico por imagem , Malha Trabecular/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Estudos Transversais , Glaucoma de Ângulo Aberto/patologia , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pessoa de Meia-Idade , Tomografia de Coerência Óptica , Malha Trabecular/patologia , Malha Trabecular/fisiopatologia
13.
PLoS One ; 15(10): e0240111, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33002090

RESUMO

PURPOSE: To investigate the relationships between global and sectoral macular vascular microcirculation parameters in the ganglion cell-inner plexiform layer (GCIPL) assessed by optical coherence tomography angiography (OCTA), and global and sectoral visual field (VF) central mean sensitivity (CMS) assessed by standard automated perimetry. METHODS: Fifty-four eyes with open angle glaucoma were scanned using a swept-source OCTA (Plex Elite 9000, Zeiss, Dublin, CA) and macular vascular microcirculation was measured by calculating the overall flux and vessel area density (VAD) over the entire 6mm x 6mm area, excluding large retinal vessels. Central 10-degree VF CMS was calculated based on 24-2 VF. Pearson correlation was used to investigate the correlation between global and sectoral OCTA parameters and global and sectoral VF CMS. RESULTS: Both global GCIPL flux and VAD were significantly correlated with VF CMS (p<0.001). For the sectoral analysis, sectoral VAD was significantly correlated with sectoral VF CMS in all comparisons except for the inferonasal VF CMS with supero-temporal (ST) GCIPL VAD (p = 0.097). Although highest correlation was observed for both ST VF CMS with inferior GCIPL VAD and infero-temporal VF CMS with superior GCIPL VAD (r = 0.683, p<0.001), there was no significant difference in correlation when compared to the global VAD and other sectors' correlation coefficients (p≥ 0.091), except for the ST GCIPL VAD (p = 0.001). CONCLUSIONS: Global and sectoral macular vascular microcirculation in the GCIPL, as determined by OCTA, was significantly correlated with global and sectoral VF CMS in glaucomatous patients. OCTA can aid in the understanding of the structure-function relationships of the macular region.


Assuntos
Glaucoma de Ângulo Aberto/fisiopatologia , Macula Lutea/irrigação sanguínea , Microcirculação , Células Ganglionares da Retina/patologia , Idoso , Idoso de 80 Anos ou mais , Glaucoma de Ângulo Aberto/diagnóstico por imagem , Glaucoma de Ângulo Aberto/patologia , Humanos , Macula Lutea/patologia , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia de Coerência Óptica , Testes de Campo Visual , Campos Visuais
14.
BMC Biomed Eng ; 2: 10, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33073174

RESUMO

BACKGROUND: A major challenge for any glaucoma implant is their ability to provide long-term intraocular pressure lowering efficacy. The formation of a low-permeability fibrous capsule around the device often leads to obstructed drainage channels, which may impair the drainage function of devices. These foreign body-related limitations point to the need to develop biologically inert biomaterials to improve performance in reaching long-term intraocular pressure reduction. The aim of this study was to evaluate in vivo (in rabbits) the ocular biocompatibility and tissue integration of a novel suprachoroidal microinvasive glaucoma implant, MINIject™ (iSTAR Medical, Wavre, Belgium). RESULTS: In two rabbit studies, no biocompatibility issue was induced by the suprachoroidal, ab-externo implantation of the MINIject™ device. Clinical evaluation throughout the 6 post-operative months between the sham and test groups were similar, suggesting most reactions were related to the ab-externo surgical technique used for rabbits, rather than the implant material itself. Histological analysis of ocular tissues at post-operative months 1, 3 and 6 revealed that the implant was well-tolerated and induced only minimal fibroplasia and thus minimal encapsulation around the implant. The microporous structure of the device became rapidly colonized by cells, mostly by macrophages through cell migration, which do not, by their nature, impede the flow of aqueous humor through the device. Time-course analysis showed that once established, pore colonization was stable over time. No fibrosis nor dense connective tissue development were observed within any implant at any time point. The presence of pore colonization may be the process by which encapsulation around the implant is minimized, thus preserving the permeability of the surrounding tissues. No degradation nor structural changes of the implant occurred during the course of both studies. CONCLUSIONS: The novel MINIject™ microinvasive glaucoma implant was well-tolerated in ocular tissues of rabbits, with observance of biointegration, and no biocompatibility issues. Minimal fibrous encapsulation and stable cellular pore colonization provided evidence of preserved drainage properties over time, suggesting that the implant may produce a long-term ability to enhance aqueous outflow.

15.
J Glaucoma ; 28(9): 790-796, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31233458

RESUMO

PRECIS: We found significant differences in macular vascular microcirculation between normal and glaucomatous eyes using optical coherence tomography angiography (OCTA). Macular vascular microcirculation changes also showed significant correlations with visual field (VF) severity classification systems. PURPOSE: To correlate VF severity defined by different classification systems and macular vascular microcirculation in eyes with glaucoma using OCTA. PATIENTS AND METHODS: Twenty normal and 58 open-angle glaucoma (OAG) eyes were scanned using a swept-source OCTA (Plex Elite 9000) and macular vascular microcirculation was measured by calculating the overall blood flux index (BFI) and vessel area density (VAD) over the entire 6×6 mm area excluding the big retinal vessels. Glaucomatous eyes were staged into severity groups based on 4 VF severity classifications: Hodapp-Parrish-Anderson scale, Glaucoma Severity Staging system, ICD-10 glaucoma staging definitions, and VF mean deviation. Central 10-degree VF mean sensitivity (CMS) was calculated based on 24-2 VF. One-way analysis of variance was used to analyze the differences and correlation between macular vascular microcirculation and other clinical parameters. RESULTS: Glaucomatous eyes had significantly lower ganglion cell and inner plexiform layer BFI and VAD (P<0.0001) compared with normal eyes. In OAG patients, BFI and VAD were significantly higher in mild OAG compared with severe OAG with all VF disease severity classification systems (P<0.001). Glaucoma Severity Staging had the highest correlation with changes in macular vascular microcirculation metrics (r=0.734 for BFI; r=0.647 for VAD) and VF CMS had highest correlation with macular vascular microcirculation metrics (r=0.887 for BFI; r=0.903 for VAD). CONCLUSION: Macular vascular microcirculation metrics detected by OCTA correlate with disease severity in glaucomatous eyes. VF CMS, calculated from only 12 tested central 10-degree points, correlated best with macular OCTA.


Assuntos
Glaucoma de Ângulo Aberto/fisiopatologia , Disco Óptico/irrigação sanguínea , Vasos Retinianos/fisiopatologia , Transtornos da Visão/fisiopatologia , Campos Visuais/fisiologia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Pressão Sanguínea/fisiologia , Feminino , Angiofluoresceinografia/métodos , Glaucoma de Ângulo Aberto/diagnóstico por imagem , Humanos , Pressão Intraocular/fisiologia , Masculino , Microcirculação/fisiologia , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos
16.
Invest Ophthalmol Vis Sci ; 59(8): 3675-3681, 2018 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-30029254

RESUMO

Purpose: The purpose of this study was to characterize the pulsatile motion of trabecular meshwork (TM) in normal subjects and demonstrate its changes in accommodation with phase-sensitive optical coherence tomography (PhS-OCT). Methods: A new PhS-OCT laboratory prototype was designed to measure pulsatile TM motion in 13 healthy humans. Two sets of images were captured in 10 subjects, first with best corrective refraction and the other with an additional 3.0 diopters of accommodation. In each image, both maximum velocity (MV) and cumulative displacement (CD) in two selected regions of TM, the internal (IMV and ICD) and external (EMV and ECD) region, were measured. Results: For all parameters the intraclass correlation coefficient was >0.75. Neither MV nor CD was significantly different between eyes in individual subjects (PIMV = 0.967, PEMV = 0.391, PICD = 0.603, PECD = 0.482). In 26 eyes, with best corrective refraction, the EMV was higher than the IMV (23.9 ± 9.8 vs. 18.9 ± 8.08 µm/s; P = 0.0001), as was the ECD compared with the ICD (0.340 ±0.125 vs. 0.264 ± 0.111 µm; P = 0.000004). With accommodation, MV and CD significantly increased (PIMV = 0.0003, PEMV = 0.0003, PICD = 0.019, and PECD = 0.007), whereas MV and CD in the external region were still larger than those in the internal area (PEMV vs. IMV = 0.009, PECD vs. ICD = 0.023). Conclusions: This study demonstrates the differences in TM motion between the internal and external regions of TM and displays its change with accommodation. The findings and good reproducibility suggest PhS-OCT helps to understand TM function in regulation of IOP, and, with further refinements, it may be useful in clinical management of glaucoma.


Assuntos
Acomodação Ocular/fisiologia , Glaucoma de Ângulo Aberto/fisiopatologia , Pressão Intraocular/fisiologia , Tomografia de Coerência Óptica/métodos , Malha Trabecular/fisiopatologia , Adulto , Feminino , Glaucoma de Ângulo Aberto/diagnóstico , Voluntários Saudáveis , Humanos , Masculino , Estimulação Luminosa/métodos , Reprodutibilidade dos Testes
17.
Ophthalmol Ther ; 7(1): 133-143, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29637411

RESUMO

INTRODUCTION: To develop a grading system that provides objective quantification of flow through the conventional aqueous humor outflow (AHO) system. The technique gives clinicians an additional assessment option in the evaluation of glaucoma treatment approaches. METHODS: This was a retrospective observational study. This study evaluated the eyes of all primary open-angle glaucoma patients who underwent a Trabectome (NeoMedix Corp., Tustin, CA, USA) procedure with or without cataract surgery in the interval between April and September 2016 (n = 73). The nasal hemisphere was divided into three regions. Utilizing a four-level grading system designed for this study, an aqueous humor outflow grade (G0-G3) was assigned to each region using a video taken during examinations. The individual grade levels of the three regions were combined to get a composite AHO score. The correlation between the composite AHO score and intraocular pressure (IOP) was then analyzed. Additionally, the speed of red blood cell (RBC) clusters in the episcleral veins (ESV) was calculated when made possible by the existence of pulsatile flow. RESULTS: At 3 months following the Trabectome procedure, average IOP decreased from 26 to 15 mmHg. Assessment of the relationship between AHO grade and IOP demonstrated that a high composite AHO score was correlated with lowered IOP (Tukey-Kramer method p < 0.05). Additionally, it was found that if one of the three regions had an AHO grade of ≥ G2, an IOP of < 20 mmHg could be predicted. (Fischer's exact test p < 0.0001). Calculated speed was as follows: at G1, the speed was 0.68 ± 0.26 mm/s (n = 7), at G2, the speed was 1.8 ± 0.84 mm/s (n = 5), and at G3, the speed was 6.8 ± 3.3 mm/s (n = 6). CONCLUSION: There was a significant correlation between an increase in the composite AHO score and a decrease in IOP. Additionally, the speed of RBC clusters as they traveled through the ESVs remained consistent for each of the grades, and the span of the speeds from lower to higher grades represented a significant range. These findings suggest that the grading system is a reliable measure of AHO. TRIAL REGISTRATION IDENTIFIER: UMIN 000031745.

18.
Exp Eye Res ; 171: 164-173, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29526795

RESUMO

Cultured trabecular meshwork (TM) cells are a valuable model system to study the cellular mechanisms involved in the regulation of conventional outflow resistance and thus intraocular pressure; and their dysfunction resulting in ocular hypertension. In this review, we describe the standard procedures used for the isolation of TM cells from several animal species including humans, and the methods used to validate their identity. Having a set of standard practices for TM cells will increase the scientific rigor when used as a model, and enable other researchers to replicate and build upon previous findings.


Assuntos
Técnicas de Cultura de Células , Separação Celular/métodos , Guias como Assunto , Malha Trabecular/citologia , Fatores Etários , Animais , Biomarcadores/metabolismo , Consenso , Feto , Humanos , Doadores de Tecidos , Preservação de Tecido , Coleta de Tecidos e Órgãos , Malha Trabecular/metabolismo
19.
Invest Ophthalmol Vis Sci ; 58(11): 4809-4817, 2017 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-28973327

RESUMO

Purpose: The purpose of this study was to estimate human trabecular meshwork (hTM) stiffness, thought to be elevated in glaucoma, using a novel indirect approach, and to compare results with direct en face atomic force microscopy (AFM) measurements. Methods: Postmortem human eyes were perfused to measure outflow facility and identify high- and low-flow regions (HF, LF) by tracer. Optical coherence tomography (OCT) images were obtained as Schlemm's canal luminal pressure was directly manipulated. TM stiffness was deduced by an inverse finite element modeling (FEM) approach. A series of AFM forcemaps was acquired along a line traversing the anterior angle on a radially cut flat-mount corneoscleral wedge with TM facing upward. Results: The elastic modulus of normal hTM estimated by inverse FEM was 70 ± 20 kPa (mean ± SD), whereas glaucomatous hTM was slightly stiffer (98 ± 19 kPa). This trend was consistent with TM stiffnesses measured by AFM: normal hTM stiffness = 1.37 ± 0.56 kPa, which was lower than glaucomatous hTM stiffness (2.75 ± 1.19 kPa). None of these differences were statistically significant. TM in HF wedges was softer than that in LF wedges for both normal and glaucomatous eyes based on the inverse FEM approach but not by AFM. Outflow facility was significantly correlated with TM stiffness estimated by FEM in six human eyes (P = 0.018). Conclusions: TM stiffness is higher, but only modestly so, in glaucomatous patients. Outflow facility in both normal and glaucomatous human eyes appears to associate with TM stiffness. This evidence motivates further studies to investigate factors underlying TM biomechanical property regulation.


Assuntos
Módulo de Elasticidade/fisiologia , Glaucoma/fisiopatologia , Tomografia de Coerência Óptica/métodos , Malha Trabecular/fisiologia , Idoso , Idoso de 80 Anos ou mais , Cadáver , Feminino , Análise de Elementos Finitos , Humanos , Masculino
20.
JAMA Ophthalmol ; 135(5): 461-468, 2017 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28358939

RESUMO

Importance: Understanding the differences in vascular microcirculation of the peripapillary retinal nerve fiber layer (RNFL) between the hemispheres in eyes with glaucoma with single-hemifield visual field (VF) defects may provide insight into the pathophysiology of glaucoma. Objective: To investigate the changes in the microcirculation of the peripapillary RNFL of eyes with glaucoma by using optical microangiography. Design, Setting, and Participants: Eyes with glaucoma and single-hemifield VF defect and normal eyes underwent scanning using an optical microangiography system covering a 6.7 × 6.7-mm2 area centered at the optic nerve head. The RNFL microcirculation was measured within an annulus region centered at the optic nerve head divided into superior and inferior hemispheres. Blood flux index (the mean flow signal intensity in the vessels) and vessel area density (the percentage of the detected vessels in the annulus) were measured. Main Outcomes and Measures: Differences in microcirculation between the hemispheres in eyes with glaucoma and normal eyes and correlations among blood flow metrics, VF thresholds, and clinical optical coherence tomography structural measurements were assessed. Results: Twenty-one eyes from 21 patients with glaucoma (7 men and 14 women; mean [SD] age, 63.7 [9.9] years) and 20 eyes from 20 healthy control individuals (9 men and 11 women; mean [SD] age, 68.3 [10.7] years) were studied. In eyes with glaucoma, the abnormal hemisphere showed a thinner RNFL (mean [SE] difference, 23.5 [4.5] µm; 95% CI, 15.1-32.0 µm; P < .001), lower RNFL blood flux index (mean [SE] difference, 0.04 [0.01]; 95% CI, 0.02-0.05; P < .001), and less vessel area density (mean [SE] difference, 0.08% [0.02%]; 95% CI, 0.05%-0.10%; P < .001) than did the normal hemisphere. Compared with normal eyes, reduced RNFL microcirculation was found in the normal hemisphere of eyes with glaucoma, measured by mean [SE] differences in blood flux index (0.06 [0.01]; 95% CI, 0.04-0.09; P < .001) and vessel area density (0.04% [0.02%]; 95% CI, 0.02%-0.08%; P = .003) but not in RNFL thickness (3.4 [4.7] µm; 95% CI, -6.2 to 12.9 µm; P = .48). Strong correlations were found between the blood flux index and VF mean deviation (Spearman ρ = 0.44; P = .045) and RNFL thickness (Spearman ρ = 0.65; P = .001) in the normal hemisphere of the eye with glaucoma. Conclusions and Relevance: Reduced RNFL microcirculation was detected in the normal hemisphere of eyes with glaucoma, with strong correspondence with VF loss and RNFL thinning. Although the results suggest that vascular dysfunction precedes structural changes seen in glaucoma, longitudinal studies would be needed to confirm this finding.


Assuntos
Glaucoma/fisiopatologia , Microcirculação/fisiologia , Disco Óptico/irrigação sanguínea , Células Ganglionares da Retina/patologia , Vasos Retinianos/fisiopatologia , Escotoma/fisiopatologia , Campos Visuais , Idoso , Feminino , Glaucoma/complicações , Glaucoma/diagnóstico , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Vasos Retinianos/diagnóstico por imagem , Escotoma/diagnóstico , Escotoma/etiologia , Tomografia de Coerência Óptica/métodos